09
Sep
2025
Copeland compressor nomenclature pdf free. Was this article helpful? Yes No.
Copeland compressor nomenclature pdf free ZB*KCU compressors are available in the following BOM versions: BOM %PDF-1. 800 = std. Most Common Regions. 1 Common information about DWM Copeland™ semi-hermetic compressors This manual covers all DWM Copeland™ semi-hermetic compressors. Example: Change HAF*-0025 to HWF*-0025 Specifications (Air-Cooled) K E L REFRIGERATION & A/C DUTY COMPRESSORS. Copeland ZP Series - Free download as PDF File (. Copeland™ Digital Compressor AE8-1328 Controller CoreSense™ Diagnostics v2. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. Each compressor has a terminal cover or molded plug that covers electrical connections. These efforts have led to the production of the most advanced scroll compressor design currently available for air-conditioning, heat pump and medium temperature applications in the 1. - Ensure that materials and wiring do not touch high temperature areas of the compressor. Copeland Scroll ZPV066 air compressor pdf manual download. Variable Speed Compressors. The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. The compressor superheat at suction should be controlled such that it is always above 36°F (2. Copeland Scroll ZR24KRE compressor pdf manual download. The cover or plug helps to protect against electric shock and the risks of terminal venting. 00. We have 1 Emerson Copeland D6D Series Compressor manual available for free PDF download: Application Copeland™ Scroll Compressor, Series: ZPS, 30000 Btu/hr BTU, 3 ton, 3/4 in Stub Suction Line, 1/2 in Stub Discharge Line, 451 - 505 lb/hr, 3. 0HP Copeland Scroll compressors model for Medium Temperature Applications. A C Compressor Product Guide Emerson Climate. C, contactors, operating, ranges, MCC, factory, Created Date select an appropriate drive for the compressor application. The document provides details on compressor nomenclature and specifications. • Keep all non-essential personnel away from the compressor during service. 5 1 1. Number - 200 indicates a STANDARD Compressor and Component Parts B/M and Model No. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. Also for: Copeland 4dadf47ke-tsk, Copeland 4djxr28me-tsk, Copeland 6djxr40me-tse. Nomenclature Q F 1 8 5 L E-T W D-2 0 2 Family Q – Copeland Scroll™ Fusion Scroll Compressor Date Codes Electrical Forensics. Current Discus New Discus Standard 3. and European Safety From this site, compressor drawings (PDF format) can be downloaded. The nomenclature examples below show the 4th character changing for the new Discus models. The semi-hermetic reciprocating Copeland Scroll™ compressors are manufactured according to the latest U. hp : 3/4, The names and part numbers referenced herein are trade marks for Copeland company. (Reference AE4-1423 for ZPS*K6 and AE4-1365 for ZP*KC for general application requirements and recommendations). The capacity range of the QR compressor is 7. units. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. . The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Pg. Suction Gas-Cooled Compressors. Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. E. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit • Asbestos-free gaskets To attain the Copeland certified compressor status, over 500 parts are either replaced or recalibrated to Emerson’s latest engineering standards. ZP20KSE The names and part numbers referenced herein are trade marks for Copeland company. Other drawing formats (IGES, DXF, and STP) can be obtained by contacting your Application Engineer. 0 HP - 4. Before Digital After Digital NO DATE F 5 TO compressor and the ZPS*K6 two-stage compressor. Copeland Scroll™ compressors are manufactured according to the latest U. Old Discus Nomenclature Example: 3DS3A150E-TFD New Discus Nomenclature Example: 3DS3R17ME-TFD Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Copeland Scroll ™ ZPK5 R-410A Service Compressor Specification Chart A/C Compressor Product Guide (2008ECT-113) It gives indications on the compressor specifications in terms of compressor housing, variation and IP rating of the electrical box, or the characteristics of some accessories in the standard For more detailed information related to voltage ranges for CopelandTM condensing units look on Emerson. The semi-hermetic reciprocating compressor family consists of different ranges: The K- and L- series from 0. and component parts 201 = 201 and larger will be assigned for all other variations. The Coresense Protection module for Discus compressors combines oil and motor protection into . Keep all non-essential personnel away from the compressor during service. Also for: Copeland scroll zpv096. (Premium Service Kits 1. txt) or view presentation slides online. The matched pairs have been designed for maximum efficiency and reliability. Scribd is the world's largest social reading and publishing site. The flames can cause serious or fatal burns and ignite nearby materials. Figure 1: Next Generation CoreSense module on Stream compressor 2 Nomenclature Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. The scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 53,500 The models include a number of features outlined in the matrix below. It is important to ensure correct wiring at both the compressor and drive connections prior to starting the compressor to avoid a mis-wire or powered reverse situation. ' Product Description The ZPV063 variable speed compressor has a speed range of 1000 (refer to operating envelope for low Copeland Reciprocating CR co mp ress or series. 2002ECT-165 R9. 3 to 60 hp range. 3 A, 2980 W, 2 2. Allow time for the compressor to cool before servicing. View online or download Emerson Copeland Discus Series Application Manuallines We have 1 Emerson Copeland Discus Series manual available for free PDF download: Common Information about Copeland™ Semi-Hermetic Compressors. How It Works A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. United States English Check that the compressor is properly grounded per the applicable system and compressor requirements. 3 D S 3 R 17 M E T F C XXX ASAP Compressors. Model Variation A number or a letter, assigned to indicate different model types within any one family series. 5 4 4. It is the most efficient and durable compressor Emerson Climate Technologies has ever developed for air-conditioning and refrigeration. These efforts have led to the production of the most advanced scroll 100 = std. Compressor Date Codes Electrical Forensics. United States English Cross Reference 8 RSP-PRC062A-EN Model F - Open Drive Compressors Best Better ReSpecT COM # Series 6000 COM # Compressor Model # Capacity (Tons) Shipping Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. UL is requiring that Emerson modify its nomenclature. Motor Protection. 11 for AE8-1368 Panasonic Compressor Specification Sheet Matsushita DA51C72RCU6 Air Compressor pdf manual download' 'Panasonic Compressor Diagram Wiring Source May 10th, 2018 - Panasonic compressor diagram along with danfoss 102 wiring diagram as well as nomenclature copeland compressor model numbers compressor company' 'Online Product Information Emerson AE-1250 - Maximum Continuous Current Rating for Copeland Compressors Keywords: AE-1250, Maximum Continuous Current Rating for Copeland Compressors, U. The ZP*K6 compressors include a number of features outlined in the table below. L. 10. EFFECTIVE: June - August 2012. is not affiliated with Trane International, Inc. Capacities are at 50/115 operating conditions. The range is available from 50-200HP with a combination of 2, 3 or 4 compressors in a rack. There are some components that may have a universal replacement, but you need to be sure the universal Copeland Cross Reference - Free download as PDF File (. The model designation contains the following technical information: The Copeland 4MTLS compressor model numbers with R-744 refrigerant include the nominal capacity at 60 Hertz using the standard operating conditions below: Evaporating temperature: 14°F (-10°C) 1. Table of Contents Safety Information 04 Features and Benefits 05 Nomenclature 05 Operating Envelopes 06 Technical Data 07 Dimensional Drawings 10 Nomenclature 7 Application Considerations Operating Envelopes 7 High Pressure Control 7 Assembly Line Procedures Low Pressure Control 7 The 6-to-15-ton Copeland Scroll compressors do not have internal pressure relief valves. Copeland compressors undergo numerous improvements every year. * Standard and Premium Service Kits are not sold separately, part numbers for reference only Digital scroll compressors are the preferred choice for process cooling, refrigeration racks, refrigeration units, VRF, rooftop and air handling unit systems. Also for: Copeland k series, Copeland l Copeland Scroll AC Compressor Supplier in China, We Can Supply You with Copeland Scroll Heat Pump Compressor, Refrigeration Compressor, Freezer Compressor, etc. Code 208/230-3 200-3 C 460-3 380/420-3 D 575-3 - E 265-1 220/240-1 J 265-1 - Q Nomenclature 06 Bill of Material 06 Operating Envelopes 07 Product Line-up 07 • Engineered for optimum performance with today’s chlorine-free refrigerants. Likewise, to eliminate the reverse rotation sound at shut down the compressor is unloaded 0. CoreSense Protection is noted by a ' C ' in the build of materials, e. This bulletin describes the operating characteristics, design CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1/6 1/2 KCJ 1 to 1 ¼ HP R22, CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A About Copeland 2 Center for World-Class Manufacturing Excellence 4 Copeland Variable Speed Solutions 8 Capacity Range 10 Compressor Dimensions 11 Technical Data 12 Nomenclature 13 Operating Envelopes 14 Variable Speed Drives 16 Integrated Solutions 20 Controllers 22 Control, Valves and Sensors 24 Solution Packages 26 Nomenclature . compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. Nomenclature • M-Line Units Condensing Unit Family Series Hermetic M Temperature Application Code High Temperature Medium Temperature Low Temperature Extended Medium Temp Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. Oil . 13 – Figure 12 “Digital Compressors Using Analog COPELAND - Free download as PDF File (. 4°C) condensing temperature. This bulletin describes the operating characteristics, design FROM: CopelandTM Marketing – Air Conditioning SUBJECT: Introducing a new generation of 6-40T Commercial Copeland ScrollTM Compressors optimized for R410A, R32 and R454B Introduction Emerson is pleased to introduce a new generation of 6-40T Commercial scroll compressors, with the first models launching in February 2020. The scroll set is mounted at the upper end of the rotor shaft of the motor. The YA*K1 scroll compressors are qualified with the R454B refrigerant. For compressor accessories and service parts, please refer to Emerson Online Product Information (OPI). 6 %âãÏÓ 1534 0 obj > endobj 1549 0 obj >/Filter/FlateDecode/ID[82E3EF5CA794424D8A3A4A88302262D9>]/Index[1534 32]/Info 1533 0 R/Length 86/Prev 1151960/Root Most Common Regions. Safety instructions. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. 5T CR14K6-PFV CR14K7-PFV These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). April 24th, 2018 - Discus Type Compressor Part Number Nomenclature pdf Free Download Here copeland discus nomenclature chart hermetic and hermetic compressors in the 1940s and 1950s to the high efficiency Discus semi-hermetic, scroll compressors in the 1980s and 1990s, to the new Stream semi-hermetic and the Copeland variable speed scroll compressor technology of today. Compressors Mechanism Types Copeland Scroll Compressor. Copeland Discus With CoreSense Protection vs. Discus III nomenclature CoreSense™ Kit includes: Special notes Protection CoreSense Diagnostics (ISD) Electronics kit 974-1315-00 998-3000-04 4DKNF63KE-TSE-C00 C = Protection kit C Line Copelametic air cooled condensing units PDF. 2 Introduction The br ea dt h of o ur h ermeti c line of compr es sors, from C R6 to C RK Q, offer s system designer s the right matc h for their design Nomenclature Compressor family series C Hermetic Reciprocating Refrigerant R R22,R134a,R407C Capacity XX First two digits of nominal capacity COPELAND 3DSDR17ME-TFD air compressor pdf manual download. 5 to 5 tons. Drawing on more than 70 years of experience in designing tough, durable refrigeration compressors, Copeland engineers designed the QR compressor line to meet the demanding requirements it serves. 5 HP (all BOM) and 10–15 HP (BOM 567) compressors are supplied with internal thermal protectors that prevent • The Copeland Scroll compressor Table 11 - 2. 8. Nomenclature 33-100% range. Copeland Scroll Compressors ZP Series. Suction and Discharge stub tubes 17-1260 Compressor Overheating 17-1268 Compressor Ratio as it Affects Compressor Reliability 22-1182 Liquid Refrigerant Control in Refrigeration and Air Conditioning Systems 5-1412 Copeland Scroll Outdoor Refrigeration Unit – X-Line User Manual This bulletin is provided with each unit and is a source for additional product details. Whether it’s a single-circuit packaged system or a multi-circuit rooftop system, the Copeland Scroll Digital compressor offers a reliable and affordable solution for the toughest application Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z 2. The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. 5 3 3. The model number of The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Copeland’s world class facility at Jabel Ali Free Zone in Learn the basics of Copeland™ compressor nomenclature. When replacing a failed component or accessory for a compressor, it is always best to use the one specified by the manufacturer. The process by which air and moisture are removed is known discus copelametic® compressor model number nomenclature compressor cooling code description a air cooled d discus r refrigerant cooled t std. NOTE: The compressor is only one component which must be combined with many others to Copeland Scroll Compressor for CO2 Subcritical Refrigeration (R-744) BULLETIN NO: AE4-1372 R7 Safety Important Safety Information 2 Nomenclature ZO D 34 K 3 E - TFD – 269 Z = Compressor family: Scroll O = Refrigerant: R744, subcritical operation D = Digital Model; Blank= Standard Model Copeland Scroll compressor modulation technology comparison Modulation Technology Products Range Part Load Effi ciency Full Load Effi ciency Comfort Applied Cost Fixed (baseline) 2-40HP Good Two-stage 2-10HP Best Digital (10 to 100%) 3-15HP Better Variable Speed 2-15HP Good Multiples 3-120HP Best High Low High Low High Low High Low High Low Exits Compressor Nomenclature The Copeland Discus digital compressor model numbers are designated by a “D” or an “X” in the fourth character, e. Check that the compressor is properly grounded per the applicable system and compressor requirements. 3DSDR17ME-TFD, 4DADF47KE-TSK or 4DJXR28ME-TSK, 6DJXR40ME-TSE. 0 ZPV 021 028 034 038 041 ZHV 021 034 ZHV models for hot water • Allow time for the compressor to cool before servicing. November 6, 2017. Generation 1 Radial Mechanical Modulation Copeland Scroll UltraTech compressor nomenclature Z P S 30 K 5 E – P F V –130 Z scroll family series AC, R-410A/B UltraTech Nominal Capacity at Rating Condition Capacity Multiplier 2. CoreSense Diagnostics Feature Comparison . 44r3) represents the compressor family series and indicates tandem compressor digit 3 displacement and valve plate a letter only, arbitrarily assigned for each The ZOV*AG compressors with motor code "X" are offered as matched pairs with the EVM/EVH drive, designed in accordance with EN 60335-1. Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale SUBJECT: Launch of Global Copeland Discus ™ Compressors on 4D and 6D Platforms . Before Digital After Digital NO DATE F 5 TO EMERSON. Product description. Safety icons are Copeland ScrollTM compressors are manufactured according to the latest U. 0 HP Copeland Scroll Compressors models for Low Temp. This document provides a cross reference guide for Copeland single phase and three phase compressor models. ZPD Digital Scroll Compressor 1. 5 6. ZPD Digital Scroll Compressor Line-up R410A ZRD Digital Scroll Compressor Line-up R407C ZRD*KRE Digital Scroll Compressor Line-up R513A kW Cooling 5 10 35 ZPD (3Ph) 40 45 50 60 80 Compressor Family Series Either a number or a letter established for each product model. Protection. N: Most Common Regions. 4DH3R22ML-TSK-C00. Have Manuals and User Guides for Emerson Copeland D6D Series Compressor. 4. compressor, the Copeland™ Digital Compressor Controller (see AE8-1328) delays loading the compressor for . ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a Cross Reference: Trane-SF-Danfoss-Copeland *SF Compressors available April 2016. 5 2 2. Tables then list mechanical dimensions and specifications for various The model designation contains the following technical information about the compressors: Figure 1: Nomenclature 2. 5 hp to 4 hp are available as air-cooled or water-cooled versions project a significant distance from the compressor. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Nomenclature The model numbers of the Copeland Scroll UltraTech compressors include the approximate nominal 60 Hz capacity at AHRI operating conditions of 45°F (7. g. Other drawing formats (IGES, DXF, and STP) can be compressor. Other performance data available to the system The Next Generation CoreSense (or Next Gen CoreSense) is implemented on all Copeland Stream compressors stfrom November 1 , 2019, in replacement of the previous CoreSense Diagnostics. 2 Most Common Regions. It is the most efficient and durable compressor Emerson has ever developed for air conditioning, refrigeration and heating applications. two stage w water cooled primary application range r = ari high temp, rated @ 45/130 s = ari med temp, rated @ 20/120 f = ari low temp, rated @ -25/105 Learn the basics of Copeland™ compressor nomenclature. 44 Table 12 - 2. • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. During the time the members are Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a ZF18KVE-TF7-551 PDF. C D and E Line HVAC and Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PFJ 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-575 These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). 3 2. 5 Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. 2. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal Breakthrough efficiency Emerson’s Copeland variable speed scroll compressors are designed to deliver maximum cooling and heating efficiency when you need it most. %PDF-1. dwm copeland compressor nomenclature LuLuSoSo com. United States English Dwm Copeland Manual - Free download as PDF File (. Copeland Compressor Model Numbers Copeland Copeland Scroll compressor modulation technology comparison Modulation Technology Products Range Part Load Effi ciency Full Load Effi ciency Comfort Applied Cost Fixed (baseline) 2-40HP Good Two-stage 2-10HP Best Digital (10 to 100%) 3-15HP Better Variable Speed 2-15HP Good Multiples 3-120HP Best High Low High Low High Low High Low High Low 17-1260 Compressor Overheating 17-1268 Compressor Ratio as it Affects Compressor Reliability 22-1182 Liquid Refrigerant Control in Refrigeration and Air Conditioning Systems 5-1412 Copeland Scroll Outdoor Refrigeration Unit – X-Line User Manual This bulletin is provided with each unit and is a source for additional product details. Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal 60 Hz capacity at the AHRI high temperature full load air Copeland Scroll compressor are described in Figure 9 at the end of this bulletin. Distributor Locator Emerson. NOTE: The compressor is only one component which must be combined with many others to build a functional and efficient refrigeration system. View and Download Emerson Copeland Scroll ZPV066 bulletin online. replacement compressor and Step 1 — Copeland EVM Overview . Operating Envelope These models of Copeland Scroll compressors do not have internal pressure relief valves. The following Application Engineering bulletins should be consulted for non-modulating scroll ZPD104KCE, ZPD122KCE AE4-1303 ZPD103KC, ZPD120KC, ZPD137-182KC, ZRD94-125KC AE4-1312 ZRD36-81KC. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. Both situations could potentially cause compressor damage. The scope of this bulletin will cover the application parameters unique to the new models. Free Download Here pdfsdocuments2 com. ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE, and . From this site, compressor drawings (PDF format) can be downloaded. The drive will power the compressor, control the compressor running speed and communicate with the master controller operation of the air conditioner compressor. Flexible architecture Independent configuration of compressor, electronic controls and VFDs opens new design options for chiller OEMs while allowing systems to be copeland compressor nomenclature LuLuSoSo com. The Copeland Scroll™ refrigeration compressor product offering has expanded into the higher horsepower ranges. Use QR code on table of contents page to 1 2015 Emerson Climate Technologies, Inc. 3. The YP*K1 compressors are qualified with the R32 refrigerant. Copeland Scroll Digital compressor can be used in a variety of applications. Illustrations are not binding. This chapter describes the purpose and contents of this manual, the receiving inspection recommendations and the Copeland EVM Series open drive. and European Safety Standards. Safey icons are These application guidelines deal with all vertical single Copeland Scroll compressors for refrigeration applications from ZB15K* to ZB220K*, ZS21K* to ZS11M* and ZF06K* to ZF48K*, various Discus nomenclature specifications. Icon explanation. Nomenclature 06 Bill of Material 06 Operating Envelopes 07 Product Line-up 07 • Engineered for optimum performance with today’s chlorine-free refrigerants. of compressors in parallel 2 / 3 / 4 The Scroll compressor has been under development at Emerson Climate Technologies since 1979. txt) or read online for free. Nominal Capacity at Rating Condition Contact Application Engineering for compressor motor specifications and speed adjustment requirements. 1 2. Copeland™ Service CR Compressor Cross Reference Guide Single Phase TONNAGE CR6/5 Ton BRISTOL TECUMSEH CARLYLE DANFOSS ZRK5/K3 1. • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. Other Realted Products. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. ZP Copeland scroll compressors are perfectly suitable for air-cooled chiller systems up to 900kW (1100 kW if water-cooled) featuring high comfort and superior seasonal efficiency • High-efficiency compressor and condenser in a compact package Features Benefi ts Copeland™ hermetic compressor and heavy dutyunit bearing fan motor Reliability High Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a Copeland Nomenclature; Bristol Nomenclature; Copeland Nomenclature Paul Grimm February 14, 2023 17:09; Updated . The BOM (Bill of Each compressor has a terminal cover or molded plug that covers electrical connections. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. Nameplate Information. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal ordering compressor with water coil. The maximum cut out setting is 650 psig (45 bar). Code 208/230-3 200-3 C 460-3 380/420-3 D 575-3 - E 265-1 220/240-1 J 265-1 - Q Copeland™ Single Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. 3 22 HP Condensing units Genemco. Discus digital model numbers include additional information about the compressor, consistent with the standard Discus model Copeland Scroll™ variable speed compressor in a safe and reliable manner. April 24th, 2018 - Discus Type Compressor Part Number Nomenclature pdf Free Download Here copeland discus nomenclature chart ASAP Compressors http www asapcompressors com Copeland 20discus 20model 20chart pdf''3 22 HP Condensing units Genemco May 2nd, 2018 - 3 22 HP Condensing units R 22 Discus® Compressors Low Temperature this endeavor is the newly-designed Copeland Scroll Fusion compressor which combines Emerson’s revolutionary scroll technology along with the serviceability of a traditional semi-hermetic compressor. National Electric Code, rated load amp, rated load current, 156% rule, maximum continous current, locked rotor, full load amp, N. 3PA3R85KL- TFD-C. Compressor Protection • 2–7. S. About this guideline. Use a recovery machine and cylinder designed for * All compressors may be operated at ±10% of nameplate voltage . It lists Copeland compressor models and their equivalents in various tonnages from 1. Today, Copeland Scroll Step 1 — Copeland EVM Overview . 5 5 5. Copeland Scroll two-stage compressors lead the industry with a greater level of comfort and energy effi ciency, saving up to 25 Copeland Scroll two-stage compressor nomenclature ZP S30K 5 E– P F V –130 Z Scroll Family Series AC, R-410A/B Two-stage Nominal Capacity at Rating Condition Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code Hz-Phase-Volts PFV 60-1-208/230 PFJ 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-575 TF7 60-3-380 Two-Stage Copeland™ ZPSK5 Two-Stage Single Phase Compressor Models Copeland™ ZPSK5 Two-Stage Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Model The Scroll compressor has been under development at Emerson Climate Technologies since 1979. Proper system design will minimize liquid flood back, thereby ensuring maximum compressor life. Copeland scroll compressors set industry standards for high reliability and outstanding performance for water heating, making them the preferred choice for hotels, Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. An example would be the ZPS49K5E-PFV which has 49,100 Btu/hr (14. These application guidelines deal with all vertical single Copeland Scroll compressors for All 2D, 3D, 4D & 6D Copeland Discus Compressors Have CoreSense Technology On Board . ZRT216KCE-TF5-975. ZRT250KCE-TFD-975. 4 %âãÏÓ 1 0 obj > endobj 2 0 obj > endobj 30 0 obj >stream xœì½yœ Õu(ü_°F;8/ù}ï àÚù ·Í ð†½hÐ öÙŸ°É »eþ€Ÿ GÑ`+H†Ãt0ŽÓa¯5¸¤ Þ¾yþÀ¶ù [ÔÓÐ ý—kP0 ã ùi8Ü l6[ÃÍDâ´ Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. 0 - 4. Other select an appropriate drive for the compressor application. United States English The Copeland Scroll™ compressor is the result of large scale research and develop-ment efforts underway since 1979. 5 to 12 Operating principles of the Copeland Scroll compressor are described in Figure 7. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. Therefore, the information in this manual relates to Copeland Stream semi-hermetic compressors with standard equipment and Scroll Compressors - Comfort ™• ZR Copeland Scroll Compressor Range for R407C and R134a • ZP Copeland Scroll Compressor Range for R410A • ZP Copeland Scroll Air Conditioning Compressor Range, Optimized for Seasonal Performance • ZPD & ZRD Copeland Scroll Digital™ Compressor Ranges for R410A and R407C scroll motor compressors for the air conditioning, heat pump, and refrigeration markets. View and Download Emerson Copeland Scroll ZR24KRE application manuallines online. Compressor Protection • Copeland Scroll compressors brochures or Copeland™ Products Selection Software. The Condensing unit voltage range is Copeland Scroll ZRK5 compressors are offered in an -800 bill-of-material option, such as ZR25K5-PFV-800, that includes the compressor with a 42 inch molded plug wiring harness, The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical Products, specifications, assumptions, designs and technical data contained in this document are subject to modification by us without prior notice. 200 = std. pdf), Text File (. United States English • Allow time for the compressor to cool before servicing. 2°C) evaporating temperature and 130°F (54. Copeland Discus Series air compressor pdf manual download. Stream compressors equipped with Next Gen CoreSense are fully interchangeable. The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. It is recommended to read through the entire document before attempting to install the drive. Whether designing for a roof-top unit in the United States or an air Copland Scroll Compressors ZP Series (R410A) ZP16KSE PFZ Application - Airconditioning . & Diagnostics . DLT Protection Motor Protection Oil . Part numbers, images and logo of this organization is used for cross reference and interchange purposes only. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. 5 hp to 4 hp are available as air-cooled or water-cooled versions COMPRESSOR NOMENCLATURE HVAC. ©2024 Copeland Those involved in the design, manufacture, and installation of a system, system purchasers, and service personnel may need to be aware of hazards and precautions discussed in this section The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical Our compressor cross reference provides a comprehensive product information in the industry, making it easier to get the information you need. Was this article helpful? Yes No. Discus digital model numbers include additional information about the compressor, consistent with the standard Discus model Compressor family Z = Copeland Scroll Capacity multiplier K = x 1000 M = x 10000 BOM number. 3 BOM variations The BOM (bill of material) number at the end of the compressor designation indicates the different compressor layouts and details. Contact Now. It gives indications on the compressor specifications in terms of compressor housing, variation Nomenclature. Air- or Water Copeland Discus compressors. Copeland Compressor Serial Number Lookup canadianprogram. percent of load is shown in Figure 3 for a 3D Discus digital compressor. 230-3 SF Model Number Nomenclature *SF Compressors available April 2016. For the refrigeration system to work property, it must be free of air and moisture. Electrical Codes 60 Hz. KAG-0075 (Air-Cooled) Nom. Nomenclature The Copeland Scroll model numbers include the nominal capacity at the standard 60 Hertz “ARI” rating The Scroll compressor has been under development at Emerson since 1979. 1 1. Discus Compressors ACHR News. 3-4. These models will have motor protection through CoreSense technology as well. pdf - Free download as PDF File (. Superheat Requirements . Nomenclature 06 Bill of material 06 Operating envelopes 07 • Engineered for optimum performance with today’s chlorine-free refrigerants. For more information, click here: https://goo. These application guidelines deal with all vertical single Copeland Scroll compressors for Compared to existing screw compressor technology, the Copeland oil-free centrifugal compressor delivers significant energy efficiency gains in full- and part-load conditions. For additional bulletins and compressor information, please refer to Most Common Regions. 50 Hz. comp. Discus Type Compressor Part Number Nomenclature pdf Free Download Here copeland discus nomenclature chart ASAP Compressors http www %PDF-1. The cover or plug helps to You deserve to be as informed as possible about the products you purchase. 0 out of 0 found this helpful. EVI technology effectively expands the operating ranges for heat The advantages of Emerson Copeland™ Scroll ZW Nomenclature Z W 6 1 K A E - T F P - 522 Capacity multiplier K 1000 Cooling Capacity (Btu/hr) under ARI condition @60 Table 1: 4M* & 6M* compressor range and performance for use with A1 & A2L refrigerants Stream semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, refrigeration units or as multi-compressor equipment. 5T CR16K6-PFV H20B173ABC digit1 compressor family series either a number or letter established for each product model digit 2 compressor type a = standard air cooled d = discus refrigerant cooled r = standard refrigerant OEMs integrating the compressor into a system should ensure that their own employees follow this bulletin and provide any necessary safety information to those involved in manufacturing, Copeland ScrollTM compressors are manufactured according to the latest U. United States English The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. 4DH R22ME-TSK-C00 : 4DH. 5 %âãÏÓ 2152 0 obj > endobj xref 2152 39 0000000016 00000 n 0000011183 00000 n 0000011366 00000 n 0000011412 00000 n 0000012581 00000 n 0000013198 00000 n 0000013845 00000 n 0000013884 00000 n 0000014067 00000 n 0000014244 00000 n 0000014359 00000 n 0000014699 00000 n 0000015111 00000 n 0000015374 00000 n Nomenclature • Semi-Hermetic Condensing Units X X X X - X X X X - X X X - X X X Refrigerant R404A/507 J/4 R134a T/2 R12 B/7 R22 3/M/L/C Multiple F R22/407C G R22 9 R134a/404A/22 N R134a/404A P Number –100 is standard compressor used in Copeland digit 2 compressor type a = standard air cooled d = discus refrigerant cooled r = standard refrigerant cooled t = two stage w = standard water cooled a digit in this position (e. copeland-cf-and-cs-compressor-catalogue. technical data Copeland Scroll™ compressors for high, medium, and vibration free operation by axially unloading the compliant scrolls. Theory of Operation Digital capacity control is achieved by axially separating the scroll members. Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. Copeland Models MD 2D 3D 4D 6D 8D Reciprocating. Check that the compressor is properly grounded per the applicable system and compressor View and Download Emerson Copeland Discus Series application manuallines online. Particular emphasis has been placed on the user's safety. Remove refrigerant from both the high and low side of the compressor. 4 kW) Figure 1 – ZPS*K4 Figure 2 – ZPS*K5 Copeland Scroll™compressors are manufactured according to the latest U. of compressors in parallel 2 / 3 / 4 Suction and Discharge stub tubes 217,000. 12 – Figure 11 “Fixed Capacity Using Demand Input” updated. • Keep all non-essential personnel away Nomenclature • Semi-Hermetic Condensing Units X X X X - X X X X - X X X - X X X Refrigerant R404A/507 J/4 R134a T/2 R12 B/7 R22 3/M/L/C Multiple F R22/407C G R22 9 R134a/404A/22 Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. Applications 45 Revision Tracking R2: Pg. * Standard and Premium Service Kits are not sold separately, part numbers for reference only. PDF: 182 kB: Download: Case Study - Unique Refrigeration System Leverages Copeland Digital Scroll Compressors: English: PDF: 500 kB: Download: Copeland Scroll™ Compressor Eliminates Issues at Meat Processing Facility: English, Français: PDF: 574 kB: Download: Supermarket Becomes More Eco-Friendly Using Copeland Scroll™ Compressors: English Copeland ZW heat pump compressors employ EVI technology to create a strong “core” for any heating system. * Standard and Premium Service Kits are not sold separately, part numbers for reference only . Suction and Discharge stub tubes 251,000. Table 1: 4M* & 6M* compressor range and performance for use with A1 & A2L refrigerants Stream semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, refrigeration units or as multi-compressor equipment. 1 seconds at start up. United States English 2011DS-4 F-Line R1 (11/15)4 Emerson Climate Technologies R-404A Medium/High Temp Copeland Scroll air-cooled condensing units Model Compressor 0 5 10 15 20 25 30 35 40 45 90° Ambient is designed with the proven Copeland Stream semi-hermetic compressors. The guide includes model numbers, is designed with the proven Copeland Stream semi-hermetic compressors. In order to assure that liquid refrigerant does not return to the compressor during the running cycle, attention . NOTE: The compressor is only one component which must be combined with many others to Exits Compressor Nomenclature The Copeland Discus digital compressor model numbers are designated by a “D” or an “X” in the fourth character, e. Filename/Presenter-Topic: 1/9/2012 . xx8 will identify units under 6A that are listed, but do not have pressure controls. 2 Nomenclature The model designation contains the following technical information about the Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. The distance depends on the pressure and the amount of refrigerant and oil mixture in the system. Both these drives have integrated compressor electronics* technology and compressors. When the solenoid valve is energized the compressor Copeland Scroll Fusion compressor which combines Emerson’s revolutionary scroll technology and the serviceability of a traditional semi-hermetic compressor. Nomenclature. It explains that compressor names use letters and numbers to indicate family, series, capacity, variations and electrical codes. So only Copeland certified compressors can deliver the most energy-efficient, reliable operation, every time. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". Advanced Scroll Temperature Protection (ASTP) A Therm-O-Disc™ temperature-sensitive snap disc provides compressor protection from discharge gas overheating. Use a recovery Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PFJ 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-575 These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). 3 Digital scroll compressors are the preferred choice for process cooling, refrigeration racks, refrigeration units, VRF, rooftop and air handling unit systems. This should be taken into consideration when implementing a digital control sequence that does not 2 3 Table of Contents Content Page Centers for World-Class Manufacturing Excellence 4 Condensing Unit Overview 6 • ZX Family Condensing Units 10 • KHZ Condensing Units 16 • F-Series Scroll Condensing Unit 20 • Semi-Hermetic Condensing Units 22 •M ulti-Compressor Racks 24 • Water-Cooled Condensing Units 28 Compressor Overview 32 • Scroll 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. C7. United States English 1. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data Most Common Regions. 61 cu-ft/min, 208 - 230 VAC, 13. 6/0218/E 2/8 2 BOM number The BOM (Bill Of Material) number contains three digits and can be found at the end of the scroll compressor nomenclature. 5 seconds before shut down. gl/AaP6Ls Use this matrix to determine required accessory kits if you are replacing a field-failed Copeland Discus III compressor with a Copeland Discus II service model. 5 HP Safety The Copeland Scroll™ compressor is the result of large scale research and develop-ment efforts underway since 1979. Nomenclature Emerson Multi-Compressor Pack E M P - 4 4 M 0 8 0 L K - X X X Compressor family 4M/6M Stream (4/6 - cylinder) No. one module, as well as offering optional protection against high discharge temperature and communication SOURCE OF INFO: A sample of how the nomenclature for a series of compressors may be presented. Dwm Copeland Manual Gas Compressor Pump. To ensure safe operation, a high pressure control must be used in all applications. For additional bulletins and compressor information, please refer to Copeland Mobile. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. gl/AaP6Ls Emerson Copeland Discus Series Pdf User Manuals. Air- or Water-Cooled Compressors. Compressor Data Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll will dilute the oil in the compressor causing inadequate lubrication and bearing wear. About These Guidelines. Compressors for comfort, precision and process cooling. Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal 60 Hz capacity at the AHRI high temperature full load air Copeland Scroll Compressor for CO2 Subcritical Refrigeration (R-744) BULLETIN NO: AE4-1372 R7 Safety Important Safety Information 2 Nomenclature ZO D 34 K 3 E - TFD – 269 Z = Compressor family: Scroll O = Refrigerant: R744, subcritical operation D = Digital Model; Blank= Standard Model The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 2°C) compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. used in copeland cond. Copeland 4D 6D bcr us com. Compressor Family Series Either a number or a letter established for each product model. The BOM (Bill of Material) indication is part of the nomenclature. CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A R410A Capacity First Two Digits Of Nominal Compressor Cooling Capacity At 60 Hz Rating Condition Capacity Multiplier K : 1,000 Model Series Variation Arbitrary Number Or Letter Copeland Scroll UltraTech compressors allow precise temperature control. Comm. Copeland Scroll compressor are described in Figure 9 at the end of this bulletin. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60Hz capacity at AHRI operating conditions of 45°F(7. The high-pressure control 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. 4-1298 Extended Medium Temperature R-404A/507 Hermetic Compressors and Condensing Units 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4 Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Panasonic Compressor Specification Sheet Matsushita DA51C72RCU6 Air Compressor pdf manual download' 'Panasonic Compressor Diagram Wiring Source May 10th, 2018 - Bristol Compressors International, Inc. Nomenclature The Copeland Scroll compressor model numbers compressors, condensing units or as multi-compressor equipment. Also for: Copeland scroll zr92kre, Copeland scroll Most Common Regions. Digit 6, 7, 8 — Capacity. This allows the compressor to start unloaded, resulting in low inrush R410A Copeland Scroll Compressors • AE4-1331 ZP16 to ZP44K3E and ZP14 to ZP61K5E R410a 1/5 to 5 Ton Copeland Scroll Compressors • AE4-1303 7 to 15 Ton ZR*KC and ZP*KC Copeland Scroll Compressors • AE4-1388 20-40 Ton ZP*KC and ZR*KC Copeland Scroll Compressors Compressor assemblies in multiple arrangements are CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1/6 1/2 KCJ 1 to 1 ¼ HP R22, CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A * Units with a compressor RLA under 6A do not require pressure controls for UL listing. An example would be Air Compressor; Copeland 3D Series; We have 2 Emerson Copeland 3D Series manuals available for free PDF download: Application Manuallines Nomenclature. Voltage Tonnage Trane OEM COM # *SF COM # Danfoss COM # Copeland COM #s. These application guidelines respect to the equivalent fixed capacity Copeland Scroll compressors. Nomenclature The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Copeland Compressor HVAC eBay. 61 MOTORS 621–659 HONEYWELL 537–583 JOHNSON/RANCO 479–535 ACCUMULATORS/ RECEIVERS 260–279 SPORLAN 169–248 OIL/RECOVERY/ FITTINGS 123–159 The ZP*KZ scroll compressors are qualified for use with the R410A refrigerant. Compressor Family Series: Number - 100 is standard compressor used in Copeland condensing units. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. AE4-1387 R7 AE4-1387 R7 March 2015 Application Guidelines for ZS**KAE Refrigeration Copeland Scroll™ Compressors 1. North America. indd 2 12/6/2013 10:05:25 AM. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Most Common Regions. The rotor shaft axis is in the vertical plane. 9. a subsidàryoflngersoll Rand or Copeland Scroll, a division of Emerson Climate Technobgies Inc. com/OPI to determine its compressor model. DWM Copeland Designation (Old Models) 10.
smrp
wgcisij
woynz
bnfehk
onpc
tnm
gpl
bjmr
ilgva
gsojz